Focused and radial shock wave therapy in orthopaedics: a 2020 instructional overview · Lab study · 2020
How do focused and radial shockwave devices differ in depth and orthopaedic uses?
This 2020 overview contrasts focused machines, which focus energy deep (past 10 cm), with radial handpieces, which fade by about 1.5 cm. It summarizes cell-repair signals and sees best support in heel pain, shoulder calcium, Achilles with exercise and unhealed bone, and poorest results in tennis elbow.
Explores how shockwave works- device types compared: deep focused and surface radial
- 2
- depth by which radial waves lose most of their strength
- 1.5 cm
- year published
- 2020
Good to know: An instructional lecture rather than a systematic review; high-energy focused waves must avoid lungs, pregnancy, severe infection and bleeding disorders.
Auersperg V, Trieb K EFORT Open Rev, 2020 · Read the paper ↗
The treatment
- Focused shock wave versus radial pressure-wave devices
- Focused generators (electro-hydraulic, piezo-electric, flat-coil and cylindrical-coil electro-magnetic) concentrate acoustic energy at depth (penetration >10 cm at high settings; peak focal pressure >50 MPa; rise time 5–10 ns at high energies). Ballistic radial devices accelerate a projectile by compressed air or electromagnetic force against an applicator, delivering maximal energy superficially at skin entry with substantial attenuation by ~1.5 cm depth, peak pressure ~15 MPa, and slower rise times (stated as ~1–25 µs in one sentence and 5–1 ms two sentences later on p. 586).
- Condition-specific dosing and co-care cited by the authors
- For pseudarthrosis and delayed fracture healing, the authors recommend high-energy focused electro-hydraulic or electro-magnetic ESWT at 0.35–0.70 mJ/mm² paired with fracture immobilization. For calcific rotator-cuff tendinitis, they cite 0.32 mJ/mm² outperforming 0.08 mJ/mm² (Gerdesmeyer 2003). For Achilles tendinopathy, they advise combining ESWT with remedial gymnastics (eccentric calf exercise). In a cited rat screw-fixation model, 3,000 unfocused shock waves at 0.3 mJ/mm² were used; in rabbit Achilles tendon, 0.6 mJ/mm² caused tendon necrosis.
- Parameter reporting and ISMST recommendations
- The authors argue that multiplying energy flux density (ED, mJ/mm²) by impulse count misstates total energy because focal-zone dimensions and pressure isobars vary across settings, note pulse-to-pulse jitter in electro-hydraulic devices, suggest momentum (M = m × v, in Ns) as an additional physical descriptor, and cite ISMST guidance to record machine type, impulse count, and ED and to cooperate with manufacturers when designing studies.
Who took part
No new patients. An instructional overview drawing on 69 earlier physics standards, cell and animal experiments, clinical studies and German insurance assessments.
Side effects
Lists pain during the session, brief skin redness, pinpoint bleeding, surface bruising, dizziness and rare deeper skin injury, without counts; lung tissue in the beam risks lung bleeding or collapse.
All the numbers and the full appraisal
What the full paper reports.
No new patient cohort or systematic study sample. Instructional lecture narratively citing 70 references (69 unique; References 1 and 31 are identical) spanning acoustic standards, in vitro and animal bone/tendon/cartilage experiments, clinical case series, randomized trials, and German health-insurance assessments.
Narrative synthesis of IEC 61846 hydrophone concepts and Figure 2 waveforms1 reported outcome
Physical distinction between focused shock waves and radial pressure waves
Narrative synthesis of IEC 61846 hydrophone concepts and Figure 2 waveforms Narrative physical comparison
Focused devices converge acoustic energy into a deep focal volume (>50 MPa peak pressure, 5–10 ns rise time at high energy, >10 cm penetration), whereas ballistic radial devices emit diverging pressure pulses strongest at skin contact and dropping markedly by ~1.5 cm (~15 MPa peak, slower rise). The authors note that which physical component — pressure gradient, temperature shift, cavitation, or momentum — drives clinical benefit remains unresolved.
Analysis details and source
Internal contradiction on p. 586 kept as printed: radial pulse rise times are stated first as 'between approximately 1 and 25 microseconds' and two sentences later as '5–1 ms'.
Narrative summary of cell and animal literature1 reported outcome
Proposed cellular mechanotransduction and preclinical bone/cartilage mechanisms
Narrative summary of cell and animal literature Qualitative mechanistic summary
Describes a mechanotransduction cascade in which cytoskeletal deformation triggers nuclear mRNA release, activating mitochondria, endoplasmic reticulum, and intracellular vesicles, alongside superoxide/free-radical induction of HIF-1 and VEGF-A, osteoclast inhibition, osteoblast and periosteal proliferation, rat knee-osteoarthritis subchondral bone rebuilding linked to Wnt5a/Ca2+ signalling, and higher rat bone density and screw pull-out stability after unfocused ESWT (3,000 pulses at 0.3 mJ/mm²).
Analysis details and source
Preclinical animal and cell findings cited selectively without sample sizes, effect estimates, or risk-of-bias appraisal; on p. 587 the text says 'we have confirmed' while citing a 2017 paper (Ref 22) authored by an unrelated research team.
Narrative clinical overview1 reported outcome
Authors' qualitative appraisal of musculoskeletal indications
Narrative clinical overview Qualitative clinical commentary
Presents strongest acceptance for plantar fasciitis (noting Germany's 2017 IQWiG assessment enabled statutory insurance reimbursement, whereas earlier trials using local anaesthesia or heterogeneous cohorts missed placebo differences), Achilles tendinopathy when paired with eccentric exercise, calcific shoulder tendinitis (citing Gerdesmeyer 2003 for 0.32 vs 0.08 mJ/mm² and Cacchio 2006 for radial vs focused), and high-energy focused ESWT (0.35–0.70 mJ/mm²) for fracture non-unions. Describes osteonecrosis, bone marrow oedema, and osteochondrosis dissecans literature as sparse without double-blind trials, states lateral epicondylitis has the worst results among recognized indications and still requires proof from upcoming studies, and briefly notes radial muscle/fascia versus focused static trigger-point applications.
Analysis details and source
Unsystematic narrative judgement without quantitative outcome extraction. Note that 'wound healing problems' are listed among addressed indications on p. 584 but never discussed in the body text.
How treatment was delivered
Focused generators (electro-hydraulic, piezo-electric, flat-coil and cylindrical-coil electro-magnetic) concentrate acoustic energy at depth (penetration >10 cm at high settings; peak focal pressure >50 MPa; rise time 5–10 ns at high energies). Ballistic radial devices accelerate a projectile by compressed air or electromagnetic force against an applicator, delivering maximal energy superficially at skin entry with substantial attenuation by ~1.5 cm depth, peak pressure ~15 MPa, and slower rise times (stated as ~1–25 µs in one sentence and 5–1 ms two sentences later on p. 586).
For pseudarthrosis and delayed fracture healing, the authors recommend high-energy focused electro-hydraulic or electro-magnetic ESWT at 0.35–0.70 mJ/mm² paired with fracture immobilization. For calcific rotator-cuff tendinitis, they cite 0.32 mJ/mm² outperforming 0.08 mJ/mm² (Gerdesmeyer 2003). For Achilles tendinopathy, they advise combining ESWT with remedial gymnastics (eccentric calf exercise). In a cited rat screw-fixation model, 3,000 unfocused shock waves at 0.3 mJ/mm² were used; in rabbit Achilles tendon, 0.6 mJ/mm² caused tendon necrosis.
The authors argue that multiplying energy flux density (ED, mJ/mm²) by impulse count misstates total energy because focal-zone dimensions and pressure isobars vary across settings, note pulse-to-pulse jitter in electro-hydraulic devices, suggest momentum (M = m × v, in Ns) as an additional physical descriptor, and cite ISMST guidance to record machine type, impulse count, and ED and to cooperate with manufacturers when designing studies.
No patient adverse-event counts are collected or tabulated. Narratively, the authors list pain during ESWT, skin reddening, petechial bleeding, superficial haematomas, vasovagal dizziness, and occasional deeper skin injuries, plus rabbit Achilles tendon necrosis at 0.6 mJ/mm² (Rompe 1998) and risk of lung tears, bleeding, or pneumothorax if lung tissue lies in the sound field; they attribute a reported case of humeral-head osteonecrosis (Durst 2002) more likely to prior repeated cortisone injections than to ESWT at recommended energies. Opening bullets list severe coagulopathy (for high-energy ESWT), fetus/embryo in the focus, and severe infection in the focus as contraindications. The authors declare no conflict of interest and no commercial benefits, though Figure 2 uses a manufacturer measurement (MTS Europe GmbH orthogold100) and p. 587 recommends cooperating with manufacturers when designing studies.
Author-reported: the physical properties required for clinical efficacy remain unclear; acoustic measurements vary across conditions and electro-hydraulic jitter complicates single-pulse measurement; double-blind trials are lacking for osteonecrosis; lateral epicondylitis has poor results requiring upcoming studies; and further randomized trials are needed across several musculoskeletal areas.
Extractor interpretation: unsystematic narrative lecture with no database search, selection criteria, risk-of-bias assessment, sample sizes, effect estimates, or confidence intervals; internal errors include radial rise time printed as both '1 and 25 microseconds' and '5–1 ms' on p. 586, 'wound healing problems' promised in the abstract (p. 584) but omitted from the body text, contraindications split inconsistently between p. 584 and p. 588, Ref 4 (a plantar-fasciitis trial) cited for lateral epicondylitis on p. 584, 'we have confirmed' written on p. 587 for another group's rat study (Ref 22), and Ref 1 duplicated as Ref 31.
Findings checked against the full source by a separate automated reviewer.
Limitations noted by the reviewers
- Author-reported: the physical properties required for clinical efficacy remain unclear; acoustic measurements vary across conditions and electro-hydraulic jitter complicates single-pulse measurement; double-blind trials are lacking for osteonecrosis; lateral epicondylitis has poor results requiring upcoming studies; and further randomized trials are needed across several musculoskeletal areas.
- Extractor interpretation: unsystematic narrative lecture with no database search, selection criteria, risk-of-bias assessment, sample sizes, effect estimates, or confidence intervals; internal errors include radial rise time printed as both '1 and 25 microseconds' and '5–1 ms' on p. 586, 'wound healing problems' promised in the abstract (p. 584) but omitted from the body text, contraindications split inconsistently between p. 584 and p. 588, Ref 4 (a plantar-fasciitis trial) cited for lateral epicondylitis on p. 584, 'we have confirmed' written on p. 587 for another group's rat study (Ref 22), and Ref 1 duplicated as Ref 31.
Source-linked critical reading
Narrative instructional lecture and clinical overview
This 2020 orthopaedic lecture explains the practical difference between focused shock wave machines (which concentrate energy deeper, including on bone) and radial pressure-wave handpieces (which deliver energy near the skin surface and lose strength by about 1.5 cm depth), and outlines common temporary side effects (treatment pain, skin reddening, pinpoint bruising, dizziness) and safety rules such as keeping lungs, severe infections, pregnancy, and severe bleeding disorders out of high-energy focal zones. Because the authors selected studies without a systematic search or critical appraisal, individual trial pages provide more reliable numbers on whether treatment helps each condition.
How do focused shock wave generators and ballistic radial pressure-wave devices differ physically, what cellular mechanisms are proposed for orthopaedic regeneration, and how do the authors summarize safety and clinical indications across bone and soft-tissue disorders?
Unsystematic instructional lecture ('Instructional Lecture: Basic Science') by two Austrian orthopaedic surgeons, citing 70 references (69 unique) across acoustic standards, cell/animal studies, clinical series, randomized trials, and German reimbursement reports, with no search strategy, inclusion criteria, risk-of-bias assessment, or outcome tables.
No new patient cohort, animal experiment, or pooled participant total. Discusses historical German orthopaedic adoption and statutory reimbursement alongside selected preclinical rat, rabbit, dog, and horse studies and human musculoskeletal series and trials.
Reviews four focused generator classes (electro-hydraulic, piezo-electric, flat-coil and cylindrical-coil electro-magnetic; >50 MPa peak focal pressure, 5–10 ns rise time, >10 cm penetration) and ballistic radial devices (~15 MPa superficial peak, substantial drop by ~1.5 cm). Recommends 0.35–0.70 mJ/mm² high-energy focused ESWT with immobilization for bone non-unions, cites 0.32 versus 0.08 mJ/mm² in calcific shoulder tendinitis, and recommends combining ESWT with eccentric exercise in Achilles tendinopathy.
No systematic comparator. Contrasts focused shock waves, radial pressure waves, and 2 MHz diagnostic ultrasound waveforms (Figure 2), and narratively mentions placebo, corticosteroid injection, eccentric exercise, core decompression, alendronate, and surgery across cited clinical studies.
No primary data or extracted clinical effect estimates are presented; outcomes consist of qualitative commentary on acoustic parameters (MPa, rise time, mJ/mm², momentum in Ns), preclinical bone/tendon/cartilage markers, adverse effects, and broad clinical impressions by indication.
The authors argue that multiplying energy flux density by pulse count ignores focal-zone geometry and isobars, summarize mechanotransduction from cytoskeletal strain to mRNA, HIF-1/VEGF-A, and Wnt5a/Ca2+ bone remodelling, and endorse ESWT most strongly for plantar fasciitis (noting Germany's 2017 IQWiG report led to statutory insurance coverage), Achilles tendinopathy with remedial gymnastics, calcific shoulder tendinitis, and high-energy focused treatment of fracture non-unions. By contrast, they describe osteonecrosis and bone-marrow-oedema data as limited without double-blind trials and state that lateral epicondylitis has the worst results of any recognized indication.
No event rates are reported. Listed side effects and risks include application pain, skin reddening, petechiae, superficial haematomas, vasovagal dizziness, occasional deeper skin injury, rabbit tendon necrosis at 0.6 mJ/mm², and lung tears or pneumothorax if lung enters the sound field, alongside opening contraindications for severe coagulopathy (high energy), fetus/embryo in focus, and severe infection in focus. The authors declare no conflicts or commercial benefits, while recommending cooperation with device manufacturers when designing studies.
Unsystematic narrative selection without sample sizes, effect sizes, confidence intervals, or bias ratings; radial rise times are printed inconsistently as '1 and 25 microseconds' and two sentences later as '5–1 ms' (p. 586); wound healing is listed in the abstract (p. 584) but absent from the body text; contraindications differ between the abstract and body section; a plantar-fasciitis trial (Ref 4) is cited for lateral epicondylitis; 'we have confirmed' is used for another group's rat study (Ref 22); and Ref 1 is duplicated as Ref 31.
Provides introductory context on focused versus radial shock wave physics, safety contraindications, and European orthopaedic practice, including regulatory differences in who may diagnose and apply ESWT. It cannot substitute for systematic reviews or primary trials when estimating clinical benefit or selecting exact doses.
Standardized acoustic reporting (focal volume, pressure isobars, momentum, and device type) paired with independent, blinded randomized trials and systematic syntheses that quantify clinical effect sizes and adverse events for each orthopaedic indication.
Read the original article.
Extracorporeal shock wave therapy: an update.
Auersperg V, Trieb K. · EFORT Open Rev · 2020
Open the publication record or available full-text files.
Checked against the full paper · Clinical review: Dr. Marcus Yu Bin Pai, · How we review →