Peripheral nerve regeneration after nerve injury or repair: preclinical rat meta-analysis · Lab study · 2018
How does shockwave affect injured nerves in animal studies?
In 3 studies of rats with a crushed or grafted sciatic nerve (110 rats), repeated shockwave sessions sped up early walking recovery at 2 weeks after nerve crush. After a nerve graft, 1 session gave early walking and nerve-fibre gains that faded by 12 weeks, though nerve signals still travelled faster.
Explores how shockwave works- rat studies of shockwave, alongside 10 of ultrasound
- 3
- rats in the shockwave studies
- 110
- weeks of follow-up in the rat nerve-graft study
- 12
Good to know: The review also analysed 10 rat studies of low-intensity ultrasound, where gains lasted longer; no study compared the two directly.
Daeschler SC, Harhaus L, Schoenle P, et al. Sci Rep, 2018 · Read the paper ↗
The treatment
- Shockwave regimens in the 3 included rat studies
- All 3 rat studies delivered 300 impulses at 3 Hz and 0.09–0.1 mJ/mm² energy flux density: Hausner 2012 (8 mm reversed sciatic autograft, N = 40) applied 300 impulses at 3 Hz and 0.1 mJ/mm² once immediately after surgery (12-week observation); Lee & Cho 2013 (sciatic crush, N = 40) applied 300 impulses at 3 Hz and 0.09 mJ/mm² 6 times over 2 weeks (2-week observation); Lee & Kim 2015 (sciatic crush, N = 30) applied 300 impulses at 3 Hz and 0.09 mJ/mm² 10 times over 2 weeks, i.e., 5 sessions/week for 2 weeks (6-week observation). Shockwave generator brand, focusing modality (focused vs defocused vs radial), coupling medium, target landmark, and post-surgery session anesthesia are not reported in the review.
- Low-intensity ultrasound regimens in the 10 included rat studies
- Started 24–72 h post-injury at intensities of 200–300 mW/cm² (7 studies) or 400–500 mW/cm² (5 studies; Jiang 2016 and Mourad 2001 contributed arms to both subgroups; studies > 500 mW/cm² were excluded), frequencies of 1.0–3.3 MHz (mostly 1.0–1.1 MHz; one Mourad 2001 arm used 0.25 MHz), continuous mode (1–2 min) or pulsed 20% duty cycle (2–5 min), from daily to once weekly over 3 to 24 weeks of follow-up.
- Comparators in included animal studies
- Sham stimulation or no post-surgical stimulation after identical rat sciatic nerve crush, autograft, or conduit surgery. No included study compared shockwave therapy directly against ultrasound.
Who took part
110 rats in 3 shockwave studies (and 445 rats in 10 low-intensity ultrasound studies) after experimental crushing or surgical grafting of the sciatic nerve; zero human studies were found.
Side effects
The study does not report side effects.
All the numbers and the full appraisal
What the full paper reports.
No human participants. Thirteen English-language preclinical rat sciatic nerve studies totaling 555 rats: 10 low-intensity ultrasound studies (N = 445 rats) and 3 extracorporeal shock wave studies (N = 110 rats). Across all 13 studies, 6 used sciatic nerve crush (axonotmesis), 2 used reversed sciatic nerve autografts (8 mm in the shockwave study, N = 40; 10 mm in an ultrasound study, N = 60), and 5 bridged 10–15 mm sciatic nerve gaps with 12–17 mm polylactic acid, polycaprolactone, or silicone conduits. Table 2 lists 16 to 70 rats per study (whereas the text on p. 2 states 20 to 60).
Sciatic Functional Index (SFI) walking-track analysis (approx. −100 complete loss to 0 uninjured)1 reported outcome
Shockwave motor function (Sciatic Functional Index) after rat nerve crush
Sciatic Functional Index (SFI) walking-track analysis (approx. −100 complete loss to 0 uninjured) Pooled preclinical rat finding (SFI points)
Pooling 2 repetitive-ESWT rat sciatic crush studies (n = 50 rats analyzed: Lee & Cho 2013 weight 76.6%, MD 18.17 [95% CI 15.24 to 21.10]; Lee & Kim 2015 weight 23.4%, MD 9.60 [95% CI 4.29 to 14.91]) gave a fixed-effect mean difference of 16.17 SFI points (95% CI 13.60 to 18.73; Z = 12.34, P < 0.00001) favoring shockwaves over untreated crush controls at 2 weeks, with substantial heterogeneity (Chi² = 7.67, df = 1, P = 0.006, I² = 87%). Both individual crush studies reported improved walking-track function starting at 2 weeks.
Analysis details and source
Preclinical rat outcome (recorded qualitatively so animal counts are not charted as human participants). Note that fixed-effect inverse-variance pooling was used despite I² = 87%, and 50 rats were analyzed out of 70 total animals listed across those two studies in Table 2.
Sciatic Functional Index, myelinated axon count, and nerve conduction velocity (NCV)1 reported outcome
Single-session shockwave motor, histological, and nerve-conduction outcomes after rat autograft
Sciatic Functional Index, myelinated axon count, and nerve conduction velocity (NCV) Single-study preclinical rat findings
In Hausner 2012 (8 mm reversed sciatic autograft, N = 40 rats, single immediate postoperative session of 300 impulses at 3 Hz and 0.1 mJ/mm²), walking-track motor function was significantly higher than control from weeks 4 to 10, but no statistically significant difference remained at 12 weeks post-injury. Myelinated nerve fiber counts (evaluated in 20 rats) were significantly higher than control at 3 weeks, with no significant difference remaining at 12 weeks. By contrast, nerve conduction velocity (evaluated in 40 rats) was significantly higher than control at 3 months (12 weeks) post-surgery; exact group means and p-values for Hausner 2012 are not printed in the review.
Analysis details and source
Demonstrates key null 12-week functional and axon-count contrasts alongside faster 12-week NCV in the only longer-term shockwave rat study.
Sciatic Functional Index, axon diameter, myelin thickness, and nerve conduction velocity1 reported outcome
Low-intensity ultrasound pooled preclinical outcomes in rat sciatic nerve models
Sciatic Functional Index, axon diameter, myelin thickness, and nerve conduction velocity Pooled preclinical rat findings
Across 8 meta-analyzed rat ultrasound studies (out of 10 included, N = 445 rats), fixed-effect analyses favored ultrasound over sham/untreated rats for SFI after nerve crush at week 2 (SMD 1.75 [95% CI 1.19 to 2.31], back-transformed DM 19.03 [13.2 to 25.6], I² = 0%, 71 rats; P < 0.00001), week 3 (SMD 1.98 [1.29 to 2.67], I² = 89%, P < 0.00001), and week 4 (SMD 3.77 [2.72 to 4.83], back-transformed DM 7.4 [5.4 to 9.5], I² = 0%, 47 rats; P < 0.00001), whereas week 1 post-crush did not differ significantly (SMD 0.34 [−0.13 to 0.81], P = 0.16, I² = 23%). After conduit or autograft repair, 200–300 mW/cm² ultrasound improved week-4 SFI (SMD 2.29 [1.10 to 3.49], P = 0.0002, I² = 0%, back-transformed DM 6.1 [4.6 to 7.7], 26 rats, pooling Jiang 2016 and two Lv 2015 entries) and 3-month conduit NCV (DM 2.82 m/s [1.37 to 4.28], I² = 0%, 16 rats). At 400–500 mW/cm², ultrasound increased conduit myelin thickness at week 4 (DM 0.06 µm [0.04 to 0.09], I² = 46%, P < 0.00001, 12 rats) and week 12 (DM 0.37 µm [0.33 to 0.40], I² = 49%, P < 0.00001) and week-4 axon diameter (DM 0.53 µm, I² = 0%, P = 0.0003, 12 rats; 95% CI [0.24 to 0.82] in Figure 5 vs [0.42 to 0.82] in text).
Analysis details and source
Comparator modality synthesized alongside shockwaves in the same review; no direct shockwave-versus-ultrasound experiment was included.
How treatment was delivered
All 3 rat studies delivered 300 impulses at 3 Hz and 0.09–0.1 mJ/mm² energy flux density: Hausner 2012 (8 mm reversed sciatic autograft, N = 40) applied 300 impulses at 3 Hz and 0.1 mJ/mm² once immediately after surgery (12-week observation); Lee & Cho 2013 (sciatic crush, N = 40) applied 300 impulses at 3 Hz and 0.09 mJ/mm² 6 times over 2 weeks (2-week observation); Lee & Kim 2015 (sciatic crush, N = 30) applied 300 impulses at 3 Hz and 0.09 mJ/mm² 10 times over 2 weeks, i.e., 5 sessions/week for 2 weeks (6-week observation). Shockwave generator brand, focusing modality (focused vs defocused vs radial), coupling medium, target landmark, and post-surgery session anesthesia are not reported in the review.
Started 24–72 h post-injury at intensities of 200–300 mW/cm² (7 studies) or 400–500 mW/cm² (5 studies; Jiang 2016 and Mourad 2001 contributed arms to both subgroups; studies > 500 mW/cm² were excluded), frequencies of 1.0–3.3 MHz (mostly 1.0–1.1 MHz; one Mourad 2001 arm used 0.25 MHz), continuous mode (1–2 min) or pulsed 20% duty cycle (2–5 min), from daily to once weekly over 3 to 24 weeks of follow-up.
Sham stimulation or no post-surgical stimulation after identical rat sciatic nerve crush, autograft, or conduit surgery. No included study compared shockwave therapy directly against ultrasound.
The review reports no adverse-event or tissue-damage data from the three included rat shockwave studies. For ultrasound, the Discussion notes that cited preclinical rat studies and UK NICE guidance on bone-healing transducers reported an absence of negative side effects or device-related adverse events. Financial support came from Deutsche Forschungsgemeinschaft (Open Access Publishing), the Baden-Württemberg Ministry of Science, Research and the Arts, and Ruprecht-Karls-Universität Heidelberg; the authors declare no competing interests.
Author-reported: small number of available studies (only 3 shockwave studies, N = 110 rats) and high risk of bias in 2 of the 3 shockwave studies; no study tested complete nerve transection with primary end-to-end repair (the commonest surgical scenario); histomorphology in graft/conduit studies sampled the mid-portion of the interponate rather than the nerve distal to the repair; and small-animal geometry leaves optimal target areas in larger human limbs uncertain.
Extractor: fixed-effect inverse-variance meta-analysis was used despite substantial heterogeneity (I² = 87% in the 2-study shockwave SFI meta-analysis and I² = 89% in week-3 ultrasound SFI); no prospective review registration (e.g., PROSPERO or SYRCLE) or publication-bias check is reported; shockwave generator type (focused vs radial) is omitted; and Figure 2 enters two subgroups from Lv 2015 (N = 16 total) as separate entries in the same fixed-effect model.
Extractor: internal text-versus-table/figure discrepancies. Study characteristics (p. 2) states animal sample sizes ranged from 20 to 60, whereas Table 2 lists 16 (Lv 2015) to 70 (Jahromy 2013); Methods (p. 7) names BIOSIS alongside PubMed and Web of Science, whereas Figure 1 accounts for all 359 records from PubMed (124) and Web of Science (235) alone; Results (p. 4) prints the 4-week ultrasound axon-diameter 95% CI as [0.42 to 0.82 µm] whereas Figure 5 prints [0.24, 0.82]; and Table 2 lists a 3-week observation period for Park 2010 alongside an 8-week regimen and week 4 and 8 outcomes.
Findings checked against the full source by a separate automated reviewer.
Limitations noted by the reviewers
- Author-reported: small number of available studies (only 3 shockwave studies, N = 110 rats) and high risk of bias in 2 of the 3 shockwave studies; no study tested complete nerve transection with primary end-to-end repair (the commonest surgical scenario); histomorphology in graft/conduit studies sampled the mid-portion of the interponate rather than the nerve distal to the repair; and small-animal geometry leaves optimal target areas in larger human limbs uncertain.
- Extractor: fixed-effect inverse-variance meta-analysis was used despite substantial heterogeneity (I² = 87% in the 2-study shockwave SFI meta-analysis and I² = 89% in week-3 ultrasound SFI); no prospective review registration (e.g., PROSPERO or SYRCLE) or publication-bias check is reported; shockwave generator type (focused vs radial) is omitted; and Figure 2 enters two subgroups from Lv 2015 (N = 16 total) as separate entries in the same fixed-effect model.
- Extractor: internal text-versus-table/figure discrepancies. Study characteristics (p. 2) states animal sample sizes ranged from 20 to 60, whereas Table 2 lists 16 (Lv 2015) to 70 (Jahromy 2013); Methods (p. 7) names BIOSIS alongside PubMed and Web of Science, whereas Figure 1 accounts for all 359 records from PubMed (124) and Web of Science (235) alone; Results (p. 4) prints the 4-week ultrasound axon-diameter 95% CI as [0.42 to 0.82 µm] whereas Figure 5 prints [0.24, 0.82]; and Table 2 lists a 3-week observation period for Park 2010 alongside an 8-week regimen and week 4 and 8 outcomes.
Source-linked critical reading
Systematic review and meta-analysis of preclinical animal studies
This systematic review found zero clinical studies in people and analyzed only rat sciatic nerve experiments, including just three shockwave studies (110 rats). In rats, shockwaves accelerated early walking-track recovery at 2 weeks after nerve crush (with high between-study inconsistency), while a single-session nerve-graft study showed temporary early gains in walking function and fiber counts that no longer differed from untreated rats at 12 weeks despite faster nerve conduction. Animal results after experimental rat nerve lesions cannot show whether shockwave therapy improves nerve recovery or hand and leg function after nerve surgery in patients.
Do postoperative extracorporeal shock wave therapy or low-intensity ultrasound accelerate motor nerve regeneration and functional recovery after peripheral nerve injury or surgical reconstruction in preclinical animal models?
PRISMA-guided systematic review and fixed-effect meta-analysis of preclinical rat studies (not prospectively registered). Database searches up to October 3, 2016 (PubMed and Web of Science in Figure 1 yielding 359 records, plus BIOSIS named in Methods, and reference screening) identified 13 English-language rat studies for qualitative synthesis (10 ultrasound, 3 shockwave) and 10 studies (8 ultrasound, 2 shockwave) for meta-analysis, appraised with the Cochrane risk-of-bias tool.
No human participants. All 13 included studies used the rat sciatic nerve model in 555 rats total: 445 rats in 10 ultrasound studies and 110 rats in 3 shockwave studies (Hausner 2012, N = 40, 8 mm reversed sciatic autograft; Lee & Cho 2013, N = 40, sciatic crush; Lee & Kim 2015, N = 30, sciatic crush). Table 2 lists 16 to 70 rats per study.
All three shockwave studies delivered 300 impulses at 3 Hz and 0.09–0.1 mJ/mm², applied once immediately after autograft surgery (0.1 mJ/mm²) or 6 or 10 times over 2 weeks after sciatic crush (0.09 mJ/mm²); shockwave device type (focused vs radial) was not reported. Ultrasound studies applied 200–500 mW/cm² at 1.0–3.3 MHz (continuous 1–2 min or 20% pulsed 2–5 min) from daily to weekly starting 24–72 h post-injury.
Sham-treated or untreated control rats undergoing the same sciatic nerve crush, reversed autograft, or synthetic conduit repair. Ultrasound and shockwave studies were analyzed separately without direct head-to-head trials.
Primary outcome: voluntary hindlimb walking-track motor function on the Sciatic Functional Index (SFI, roughly −100 after complete axonal loss to 0 in uninjured rats). Secondary outcomes: myelinated axon count or density, axon diameter, and myelin thickness (distal to crush or mid-graft/conduit), plus nerve conduction velocity (NCV) and compound muscle action potential (CMAP), followed for 2 to 12 weeks in shockwave studies and 3 to 24 weeks in ultrasound studies.
Pooling two shockwave crush studies (50 rats analyzed) showed higher 2-week SFI scores than untreated controls (fixed-effect MD 16.17, 95% CI 13.60 to 18.73; P < 0.00001), with substantial heterogeneity (I² = 87%). In the single-session autograft study (N = 40), SFI at weeks 4–10 and week-3 myelinated fiber counts (n = 20) exceeded controls, but neither differed significantly from controls at 12 weeks, whereas 12-week NCV (n = 40) remained faster. Pooled rat ultrasound analyses showed sustained gains in week-2 and week-4 SFI (not week 1), conduit myelin thickness and axon diameter, and 3-month NCV, prompting the authors to recommend clinical testing of ultrasound rather than shockwaves.
No adverse events or local tissue harms were reported for the three rat shockwave studies; the Discussion cites absence of negative side effects only for preclinical and bone-healing ultrasound transducers. Funded by Deutsche Forschungsgemeinschaft, the Baden-Württemberg Ministry of Science, Research and the Arts, and Ruprecht-Karls-Universität Heidelberg; the authors declared no competing interests.
Shockwave data came from only three rat studies (110 rats), two rated at high risk of attrition or other bias, pooled with a fixed-effect model despite I² = 87%, and lacking shockwave generator details or harms reporting. No study tested complete nerve transection with primary suture repair, graft histology sampled mid-graft rather than distal nerve, and minor discrepancies appear between text, tables, and figures (sample-size range 20–60 vs 16–70; BIOSIS count missing from Figure 1; axon-diameter lower CI 0.42 vs 0.24 µm; Park 2010 observation duration).
Preclinical rodent evidence only; zero human nerve-repair trials were found. Small-animal sciatic crush and short-gap autograft results—where functional and axon-count differences after single-session shockwave treatment vanished by 12 weeks—cannot guide clinical care after human peripheral nerve surgery.
Rigorously blinded preclinical studies specifying shockwave generator physics, repeated dosing schedules, distal nerve reinnervation, and safety after primary end-to-end nerve repair, before any randomized sham-controlled clinical trials in human nerve-surgery patients are considered.
Read the original article.
Ultrasound and shock-wave stimulation to promote axonal regeneration following nerve surgery: a systematic review and meta-analysis of preclinical studies.
Daeschler SC, Harhaus L, Schoenle P, Boecker A, Kneser U, Bergmeister KD. · Sci Rep · 2018
Open the publication record or available full-text files.
Checked against the full paper · Clinical review: Dr. Marcus Yu Bin Pai, · How we review →