Focused versus radial shockwaves for noncalcific rotator cuff tendinopathy · Randomized trial · 2021
Does focused or radial shockwave work better for rotator cuff tendon pain?
In this trial, four weekly sessions of focused or radial shockwave eased shoulder pain similarly over the first 12 weeks. Later on, focused shockwave pulled ahead: pain fell from 5.9 to 2.7 out of 10 at 24 weeks and 1.4 at 48 weeks, versus 5.5 to 4.5 and 3.0 with radial shockwave.
Focused helped more than radial from 24 weeks- adults with noncalcific rotator cuff tendon pain (44 analysed)
- 46
- weekly sessions in both groups
- 4
- weeks of follow-up after treatment
- 48
Good to know: There was no sham or exercise-only group, and each wave type used a different device.
Li C, Li Z, Shi L, et al. Biomed Res Int, 2021 · Read the paper ↗
How this study worked
What happened
Shoulder pain over a year
0–10 pain scale · start to 48 weeks after treatment
Focused shockwaveRadial shockwave
Show the numbers
| Group | Start | 4 wk after | 12 wk after | 24 wk after | 48 wk after |
|---|---|---|---|---|---|
| Focused shockwave | 5.9 | 4.8 | 3.9 | 2.7 | 1.4 |
| Radial shockwave | 5.5 | 4.8 | 4.5 | 4.5 | 3 |
The treatment
Focused shockwave
Focused, once a week for 4 weeks
- Sessions
- 4, one a week
- Pulses
- 3,000 per session
- Strength
- 0.09mJ/mm² average delivered; stepped up from 0.013 to at most 0.150 mJ/mm² as tolerated · 5.1 per second
- Numbing
- None
- Device
- Dornier Aries
- Everyone also got
- Active shoulder movement encouraged; no heavy lifting for 12 months or other therapies
Radial shockwave
Radial, once a week for 4 weeks
- Sessions
- 4, one a week
- Pulses
- 3,000 per session
- Strength
- 4.0bar average delivered; stepped up from 1.0 bar as tolerated · 3.2 per second
- Numbing
- None
- Device
- ZhuHai Hema
- Everyone also got
- Active shoulder movement encouraged; no heavy lifting for 12 months or other therapies
Compared with: Focused shockwave and radial shockwave compared directly, without a sham or exercise-only group
Bar is a pressure setting and mJ/mm² is energy per area, so the two can’t be converted into each other. Settings are what each study used, not a prescription.
This protocol among the library’s
Each dot is a group treated with shockwaves in a study in this library, at the midpoint when the paper gave a range. The dark dots are this study.
Of the other 36 groups: 7 lower, 1 the same, 28 higher.
Of the other 47 groups: 44 lower, 3 the same.
Of the other 97 groups: 69 lower, 15 the same, 13 higher.
Of the other 111 groups: 69 lower, 23 the same, 19 higher.
Energy compares only within one measure: mJ/mm² in focused waves; bar in radial waves is the device’s firing pressure, not energy in tissue. Every protocol in the library →
Who took part
46 adults aged 21–75 in Beijing, China, with MRI-confirmed rotator cuff tendinopathy (no calcium deposits or full-thickness tears) for about 14 weeks on average; 44 completed follow-up.
hollow squares: no final score
Side effects
With focused shockwave: moderate pain (5 people), skin redness (2) and fainting (1). With radial shockwave: moderate pain (3) and migraine (1). Everyone completed all 4 sessions.
All the numbers and the full appraisal
The results, in numbers.
Outpatients aged 21 to 75 years at China-Japan Friendship Hospital (Beijing, China) with noncalcific rotator cuff tendinopathy for at least 3 months: baseline NRS pain ≥5, shoulder pain and/or overhead exacerbation, decreased flexion/abduction/internal and external rotation ROM, MRI signal-intensity changes without full-thickness rotator cuff tear, and plain radiographs excluding calcific tendinopathy. Among 44 analysed patients (22 shoulders per group), Group A (F-SWT) had 10 men/12 women, mean age 50.6 ± 5.2 years, and symptom duration 14.3 ± 2.2 weeks; Group B (R-SWT) had 9 men/13 women, mean age 53.4 ± 6.7 years, and symptom duration 14.0 ± 2.4 weeks.
23 participants randomized and all 23 completed 4 sessions; 1 lost to follow-up due to changed contact information, leaving 22 participants (22 shoulders, one affected shoulder per person: 18 right, 4 left) analysed in Tables 1–4.
23 participants randomized and all 23 completed 4 sessions; 1 lost to follow-up due to changed contact information, leaving 22 participants (22 shoulders, one affected shoulder per person: 20 right, 2 left) analysed in Tables 1–4.
Shoulder pain intensity at 24 weeks (primary timepoint)4 reported outcomes
Shoulder pain intensity at 24 weeks (primary timepoint)
11-point Numerical Rating Scale (NRS, 0–10) Points
| Group | n | Baseline | Follow-up |
|---|---|---|---|
| Focused shockwave therapy (F-SWT, Group A) | 22 | 5.9 (SD 0.9) | 2.7 (SD 1) |
| Radial shockwave therapy (R-SWT, Group B) | 22 | 5.5 (SD 0.7) | 4.5 (SD 1.2) |
SD: standard deviation. CI: confidence interval. IQR: interquartile range. —: not extracted.
Focused SWT versus radial SWT
At the primary 24-week endpoint, mean NRS pain was significantly lower after focused SWT than radial SWT (2.7 ± 1.0 vs 4.5 ± 1.2; p<0.001), from comparable baselines (5.9 ± 0.9 vs 5.5 ± 0.7; p=0.20).
Analysis details and source
Although Methods 2.4 defines the primary endpoint as change in NRS from baseline to week 24, Table 2 reports visit means ± SD and unpaired t-test p-values without printing change means/SDs or between-group confidence intervals.
Shoulder pain intensity at 4 weeks
11-point Numerical Rating Scale (NRS, 0–10) Points
| Group | n | Baseline | Follow-up |
|---|---|---|---|
| Focused shockwave therapy (F-SWT, Group A) | 22 | 5.9 (SD 0.9) | 4.8 (SD 0.8) |
| Radial shockwave therapy (R-SWT, Group B) | 22 | 5.5 (SD 0.7) | 4.8 (SD 0.9) |
SD: standard deviation. CI: confidence interval. IQR: interquartile range. —: not extracted.
Focused SWT versus radial SWT
At 4 weeks post-treatment, mean NRS pain was identical in both groups (4.8 ± 0.8 vs 4.8 ± 0.9; p=0.73).
Analysis details and source
Null early secondary comparison (22 shoulders per group).
Shoulder pain intensity at 12 weeks
11-point Numerical Rating Scale (NRS, 0–10) Points
| Group | n | Baseline | Follow-up |
|---|---|---|---|
| Focused shockwave therapy (F-SWT, Group A) | 22 | 5.9 (SD 0.9) | 3.9 (SD 1.4) |
| Radial shockwave therapy (R-SWT, Group B) | 22 | 5.5 (SD 0.7) | 4.5 (SD 1) |
SD: standard deviation. CI: confidence interval. IQR: interquartile range. —: not extracted.
Focused SWT versus radial SWT
At 12 weeks post-treatment, mean NRS pain did not differ significantly between focused and radial SWT (3.9 ± 1.4 vs 4.5 ± 1.0; p=0.07).
Analysis details and source
Null 12-week comparison.
Shoulder pain intensity at 48 weeks
11-point Numerical Rating Scale (NRS, 0–10) Points
| Group | n | Baseline | Follow-up |
|---|---|---|---|
| Focused shockwave therapy (F-SWT, Group A) | 22 | 5.9 (SD 0.9) | 1.4 (SD 1) |
| Radial shockwave therapy (R-SWT, Group B) | 22 | 5.5 (SD 0.7) | 3 (SD 0.8) |
SD: standard deviation. CI: confidence interval. IQR: interquartile range. —: not extracted.
Focused SWT versus radial SWT
At 48 weeks post-treatment, mean NRS pain remained significantly lower after focused SWT than radial SWT (1.4 ± 1.0 vs 3.0 ± 0.8; p<0.001).
Analysis details and source
Completer analysis of 22 participants per group after 1 loss to follow-up per group.
Shoulder function (Total Constant-Murley Scale) at 12 weeks3 reported outcomes
Shoulder function (Total Constant-Murley Scale) at 12 weeks
Constant-Murley Scale (CMS, 0–100 points) Points
| Group | n | Baseline | Follow-up |
|---|---|---|---|
| Focused shockwave therapy (F-SWT, Group A) | 22 | 66.7 (SD 6.2) | 73.6 (SD 6) |
| Radial shockwave therapy (R-SWT, Group B) | 22 | 65.8 (SD 4.7) | 71.2 (SD 5.2) |
SD: standard deviation. CI: confidence interval. IQR: interquartile range. —: not extracted.
Focused SWT versus radial SWT
Total CMS shoulder function did not differ significantly between focused and radial SWT at 4 weeks (70.5 ± 4.3 vs 70.3 ± 4.7; p>0.05) or 12 weeks (73.6 ± 6.0 vs 71.2 ± 5.2; p>0.05).
Analysis details and source
0–100 scale confirmed in Methods 2.4 p. 3 (higher score = better shoulder function). Baseline unpaired t-test p=0.57 (Table 1).
Shoulder function (Total Constant-Murley Scale) at 24 weeks
Constant-Murley Scale (CMS, 0–100 points) Points
| Group | n | Baseline | Follow-up |
|---|---|---|---|
| Focused shockwave therapy (F-SWT, Group A) | 22 | 66.7 (SD 6.2) | 79.6 (SD 5.6) |
| Radial shockwave therapy (R-SWT, Group B) | 22 | 65.8 (SD 4.7) | 75 (SD 5.4) |
SD: standard deviation. CI: confidence interval. IQR: interquartile range. —: not extracted.
Focused SWT versus radial SWT
At 24 weeks, total CMS favored focused over radial SWT (79.6 ± 5.6 vs 75.0 ± 5.4; p=0.007), driven by higher Pain (12.7 ± 2.5 vs 10.7 ± 2.8; p=0.015) and ADL (17.0 ± 2.0 vs 14.7 ± 2.6; p=0.002) subscores, whereas ROM (34.3 ± 2.2 vs 33.9 ± 2.9; p>0.05) and Power (15.9 ± 2.6 vs 15.7 ± 3.3; p>0.05) did not differ.
Analysis details and source
Subscale native maxima in Table 1: Pain 15, ADL 20, ROM 40, Power 25.
Shoulder function (Total Constant-Murley Scale) at 48 weeks
Constant-Murley Scale (CMS, 0–100 points) Points
| Group | n | Baseline | Follow-up |
|---|---|---|---|
| Focused shockwave therapy (F-SWT, Group A) | 22 | 66.7 (SD 6.2) | 83.6 (SD 6) |
| Radial shockwave therapy (R-SWT, Group B) | 22 | 65.8 (SD 4.7) | 76.8 (SD 6.5) |
SD: standard deviation. CI: confidence interval. IQR: interquartile range. —: not extracted.
Focused SWT versus radial SWT
At 48 weeks, total CMS remained higher after focused than radial SWT (83.6 ± 6.0 vs 76.8 ± 6.5; p=0.001), with higher Pain (13.6 ± 2.3 vs 11.6 ± 2.8; p=0.012), ADL (17.7 ± 1.9 vs 16.0 ± 2.4; p=0.016), and ROM (36.0 ± 3.0 vs 34.1 ± 2.9; p=0.035) subscores.
Analysis details and source
Discussion p. 6 (bottom right) contains an apparent typographical slip stating 'greater improvement ... in the R-SWT group' while arguing for F-SWT.
Shoulder strength (CMS Power subscale) at 48 weeks1 reported outcome
Shoulder strength (CMS Power subscale) at 48 weeks
Constant-Murley Scale Power subscale (0–25 points) Points
| Group | n | Baseline | Follow-up |
|---|---|---|---|
| Focused shockwave therapy (F-SWT, Group A) | 22 | 14.5 (SD 4) | 16.3 (SD 2.6) |
| Radial shockwave therapy (R-SWT, Group B) | 22 | 14 (SD 4.3) | 15.1 (SD 3.1) |
SD: standard deviation. CI: confidence interval. IQR: interquartile range. —: not extracted.
Focused SWT versus radial SWT
CMS shoulder strength (Power, 0–25 points) did not differ significantly between focused and radial SWT at 4, 12, 24, or 48 weeks (16.3 ± 2.6 vs 15.1 ± 3.1 at 48 weeks; all p>0.05).
Analysis details and source
Null subscale across every follow-up visit.
MRI rotator cuff grade reduction (>=1 Sein grade) at 24 weeks1 reported outcome
MRI rotator cuff grade reduction (>=1 Sein grade) at 24 weeks
3.0-T T2-weighted MRI Sein grading (Grades I–IV) Patients
Focused SWT versus radial SWT ordinal MRI grade distribution at 6 months
At 24 weeks (6 months), 18 of 22 (82%) focused-SWT patients versus 5 of 22 (23%) radial-SWT patients improved by at least one Sein MRI grade; ordinal MRI distributions favored focused SWT (Grades I/II/III/IV: 4/12/6/0 vs 2/6/14/0; Mann–Whitney p=0.024, from baseline 0/4/16/2 vs 0/6/15/1, p=0.394).
Analysis details and source
At 48 weeks (12 months, Table 4 p. 7), ordinal MRI distributions also favored focused SWT (Grades I/II/III/IV: 8/14/0/0 [22/22 Grade I–II] vs 4/13/5/0 [18/22 Grade II–III]; Mann–Whitney p=0.032). Results 3.4 p. 4 states 22/22 vs 11/22 decreased 'more than one grade' at 48 weeks, which is arithmetically impossible for the 4 baseline Grade II patients in Group A because Grade I (normal tendon) is the lowest grade; the text likely meant 'at least one grade'.
How treatment was delivered
Dornier Aries electromagnetic focused device: 4 weekly sessions (5–9 day intervals), 3,000 shocks per session with ultrasound gel. Started at level 2 (0.013 mJ/mm², 16 Hz) for 160 shots and stepped up one level every 160 shots to maximum tolerated (typically levels 6–10; max level 10 = 0.150 mJ/mm² at 4 Hz), yielding a delivered mean EFD of 0.09 ± 0.018 mJ/mm² and mean frequency of 5.11 ± 0.46 Hz (5.1 ± 0.5 Hz in Abstract).
ZhuHai Hema pneumatic radial device with a 15 mm (R15) applicator: 4 weekly sessions (5–9 day intervals), 3,000 shots per session with ultrasound gel. Started at 1.0 bar (5 Hz) for 200 shots and stepped up 1 bar every 200 shots to maximum tolerated (typically 4.0–5.0 bar at 3 Hz), yielding a delivered mean pressure of 4.0 ± 0.35 bar and mean frequency of 3.2 ± 0.0 Hz (retained in bar without converting to mJ/mm², although Discussion p. 7 remarks that 4.0 bar roughly corresponds to 0.2 mJ/mm²).
Tendinopathy zones identified on 3.0-T MRI were marked with the patient seated in tendon-specific postures (hand behind back internally rotated for supraspinatus; arm externally rotated in front for subscapularis; arm slightly internally rotated in front for infraspinatus/teres minor). No local anesthesia, analgesics, or NSAIDs were used during sessions; NSAIDs were discouraged during the 4-week treatment window, heavy lifting was restricted for 12 months, immediate active shoulder motion was encouraged, and no other therapies were permitted during the 48-week study.
Adverse events were solicited via clinical exam, MRI, and patient feedback (redness, bruising, ecchymosis, hematoma, swelling, paresthesia, hypoesthesia, myalgia, gel rash/itching, and other events). In the F-SWT group, 5 patients reported moderate pain, 1 reported syncope, and 2 had skin redness; in the R-SWT group, 3 reported moderate pain and 1 reported migraine, with no other adverse effects and all 23 randomized patients per group completing all 4 sessions. Whether event counts overlapped within the same participants was not stated. Supported by public Chinese research grants (Beijing Natural Science Foundation, National Natural Science Foundation of China, and Peking Union Medical College); no competing interests declared.
Absence of sham or conservative-care control and unblinded treatment delivery: neither patients nor therapists were blinded because the focused and radial devices produced different sounds (Methods 2.2 p. 2), and lack of a sham or exercise-only group prevents separating shockwave effects from natural recovery over 48 weeks (author-reported, Discussion p. 7).
Co-varying shockwave parameters across different devices: Group A used a Dornier Aries electromagnetic focused unit (mean 0.09 ± 0.018 mJ/mm² at 5.11 ± 0.46 Hz) while Group B used a ZhuHai Hema pneumatic radial unit (mean 4.0 ± 0.35 bar at 3.2 ± 0.0 Hz), confounding modality with manufacturer, intensity profile, and pulse frequency (author-reported, Discussion p. 7).
Statistical and reporting inconsistencies: primary and secondary outcomes were defined as changes from baseline, yet Tables 2–3 report only visit scores tested with cross-sectional unpaired t-tests without confidence intervals or multiplicity adjustment; 2 lost participants were excluded from analysis; Methods 2.2 states enrollment ran June 2018–February 2020 whereas Results 3.1 states June 2018–February 2019 (with ChiCTR1900022932 registered in 2019); Results 3.4 misstates 'more than one grade' for 48-week MRI shifts; and Discussion p. 6 has a typo naming R-SWT instead of F-SWT.
Findings checked against the full source by a separate automated reviewer.
Limitations noted by the reviewers
- Absence of sham or conservative-care control and unblinded treatment delivery: neither patients nor therapists were blinded because the focused and radial devices produced different sounds (Methods 2.2 p. 2), and lack of a sham or exercise-only group prevents separating shockwave effects from natural recovery over 48 weeks (author-reported, Discussion p. 7).
- Co-varying shockwave parameters across different devices: Group A used a Dornier Aries electromagnetic focused unit (mean 0.09 ± 0.018 mJ/mm² at 5.11 ± 0.46 Hz) while Group B used a ZhuHai Hema pneumatic radial unit (mean 4.0 ± 0.35 bar at 3.2 ± 0.0 Hz), confounding modality with manufacturer, intensity profile, and pulse frequency (author-reported, Discussion p. 7).
- Statistical and reporting inconsistencies: primary and secondary outcomes were defined as changes from baseline, yet Tables 2–3 report only visit scores tested with cross-sectional unpaired t-tests without confidence intervals or multiplicity adjustment; 2 lost participants were excluded from analysis; Methods 2.2 states enrollment ran June 2018–February 2020 whereas Results 3.1 states June 2018–February 2019 (with ChiCTR1900022932 registered in 2019); Results 3.4 misstates 'more than one grade' for 48-week MRI shifts; and Discussion p. 6 has a typo naming R-SWT instead of F-SWT.
Source-linked critical reading
Single-center randomized assessor-blinded clinical trial in China (ChiCTR1900022932); 46 randomized (23 per arm) and 44 analysed (22 per arm) up to 48 weeks.
For shoulder pain from noncalcific rotator cuff tendinopathy without a full-thickness tear, four weekly sessions of focused and radial shockwaves gave similar results through 12 weeks, whereas focused shockwaves led to less pain, better overall shoulder function, and clearer tendon MRI improvement at 6 and 12 months (including one brief fainting episode and temporary soreness during treatment). Studies with a sham or exercise comparison are still needed to show how much either treatment adds beyond supervised rehabilitation.
In adults with MRI-confirmed noncalcific rotator cuff tendinopathy without full-thickness tears, how do four weekly sessions of electromagnetic focused shockwaves compare with pneumatic radial shockwaves for shoulder pain, Constant-Murley function, and tendon MRI appearance up to 48 weeks?
Single-center randomized clinical trial at China-Japan Friendship Hospital, Beijing (Ethics No. 2009-2012; ChiCTR1900022932), using computer-generated block-4 randomization (1:1) sealed in opaque envelopes. Outcome assessors, consensus musculoskeletal radiologists, and statisticians were blinded; patients and therapists were unblinded. Sixty patients were screened, 46 randomized (23 per group), all 46 finished 4 sessions, and 44 (22 shoulders per group; 1 contact loss per group) were analysed through 48 weeks.
Outpatients aged 21–75 years with shoulder pain ≥5 on a 0–10 NRS, overhead pain exacerbation, restricted flexion/abduction/internal and external rotation for ≥3 months, MRI rotator cuff T2 signal changes without full-thickness tear, and radiographs excluding calcification. Prior shoulder surgery or failed ESWT, significant muscle atrophy, steroid injection/needling <6 weeks, and PRP/stem cells <3 months were exclusions. Analysed groups (22 each) had mean ages 50.6 ± 5.2 and 53.4 ± 6.7 years, 10/12 and 9/13 men/women, and symptom durations 14.3 ± 2.2 and 14.0 ± 2.4 weeks.
Four weekly sessions (5–9 day intervals) of 3,000 focused shockwaves using an electromagnetic Dornier Aries unit over MRI-guided skin markings in seated tendon-exposing postures, without local anesthesia. Energy stepped up from level 2 (0.013 mJ/mm², 16 Hz) every 160 shots to maximum tolerated (up to level 10, 0.150 mJ/mm², 4 Hz), averaging 0.09 ± 0.018 mJ/mm² and 5.11 ± 0.46 Hz.
Four weekly sessions of 3,000 radial shockwaves using a ZhuHai Hema pneumatic device (15 mm R15 applicator), stepped up from 1.0 bar (5 Hz) every 200 shots to maximum tolerated (up to 5.0 bar, 3 Hz), averaging 4.0 ± 0.35 bar and 3.2 ± 0.0 Hz. No local anesthesia, NSAIDs, or other therapies were allowed during the 48-week study; immediate active motion was encouraged while avoiding heavy lifting for 12 months. No sham or exercise-only arm was included.
Assessed at baseline and 4, 12, 24, and 48 weeks post-treatment: 11-point NRS pain (0–10; 24-week comparison primary) and Constant-Murley Scale (CMS, 0–100, higher better; subscales Pain 15, ADL 20, ROM 40, Power 25), plus blinded 3.0-T MRI Sein tendinopathy grading (Grades I–IV) at baseline, 24 weeks, and 48 weeks, and solicited adverse events.
No statistically significant differences appeared at 4 or 12 weeks on NRS (4.8 ± 0.8 vs 4.8 ± 0.9, p=0.73; 3.9 ± 1.4 vs 4.5 ± 1.0, p=0.07) or total CMS (70.5 ± 4.3 vs 70.3 ± 4.7; 73.6 ± 6.0 vs 71.2 ± 5.2; both p>0.05). Focused SWT outperformed radial SWT at 24 weeks (NRS 2.7 ± 1.0 vs 4.5 ± 1.2, p<0.001; CMS 79.6 ± 5.6 vs 75.0 ± 5.4, p=0.007) and 48 weeks (NRS 1.4 ± 1.0 vs 3.0 ± 0.8, p<0.001; CMS 83.6 ± 6.0 vs 76.8 ± 6.5, p=0.001). CMS Power never differed (p>0.05), and ROM differed only at 48 weeks (36.0 ± 3.0 vs 34.1 ± 2.9, p=0.035). Blinded MRI grades favored focused SWT at 24 weeks (≥1-grade improvement in 18/22 vs 5/22; p=0.024) and 48 weeks (Grades I/II/III: 8/14/0 vs 4/13/5; p=0.032).
Solicited adverse events in the focused-SWT group were moderate pain (5 patients), syncope (1), and skin redness (2); in the radial-SWT group, moderate pain (3) and migraine (1), with no treatment discontinuations. Overlap of events within individuals was not specified. Funded by Beijing and National Natural Science Foundations and Peking Union Medical College; no competing interests were declared.
Unblinded patients and therapists and absence of a sham or structured-rehabilitation control group leave expectation and natural history uncontrolled. The two arms differed in device manufacturer, tolerance-adjusted dosing, and pulse frequency (5.11 vs 3.2 Hz). Cross-sectional unpaired t-tests were reported on visit scores rather than mixed-model change contrasts with confidence intervals, 2 lost patients were excluded, recruitment end dates conflict between Methods (Feb 2020) and Results (Feb 2019), 48-week MRI text says 'more than one grade' where Grade II-to-I shifts are one grade, and Discussion p. 6 has a typo naming R-SWT instead of F-SWT.
Applies to subacute-to-chronic (~14 weeks mean duration) MRI-verified noncalcific rotator cuff tendinopathy without full-thickness tears treated without concurrent physical therapy or NSAIDs. Results may not generalize to long-standing tendinopathy (>6–12 months), partial tears combined with supervised exercise, or radial protocols using different applicators, pressures, or higher frequencies.
Multicenter trials comparing focused and radial shockwaves alongside guideline-recommended progressive rotator cuff loading and a sham control, with matched frequencies, intention-to-treat longitudinal models, and 95% confidence intervals.
Read the original article.
Effectiveness of Focused Shockwave Therapy versus Radial Shockwave Therapy for Noncalcific Rotator Cuff Tendinopathies: A Randomized Clinical Trial.
Li C, Li Z, Shi L, Wang P, Gao F, Sun W. · Biomed Res Int · 2021
Open the publication record or available full-text files.
Checked against the full paper · Clinical review: Dr. Marcus Yu Bin Pai, · How we review →