Frozen shoulder (adhesive capsulitis): adjunctive shockwave therapy · Review · 2022
Does adding shockwave to routine care help frozen shoulder?
In this review of 20 trials, adding shockwave to routine care such as mobilization, physiotherapy, injections or acupuncture lowered pain by about 1.1 points more right after treatment (15 trials) and improved function. In 3 trials at 3 to 6 months, pain was about 0.9 points lower, though results varied.
Helped pain right after treatment when added to care- trials adding shockwave to routine frozen-shoulder care
- 20
- people across the 15 immediate-pain trials
- 1,084
- sessions over 2 to 8 weeks
- 2–10
Good to know: Every trial added shockwave to another treatment, such as mobilization, physiotherapy, injections or acupuncture.
Zhang R, Wang Z, Liu R, et al. Orthop J Sports Med, 2022 · Read the paper ↗
How this study worked
What happened
- studies
- 20
- Compared with
- The same routine care alone: manual mobilization, rehabilitation, shoulder injections, massage, acupuncture, taping or oral steroid with electrical stimulation (TENS)
Frozen-shoulder pain: shockwave + care vs care alone
Difference in pain score · below zero means less pain when shockwave was added
Show the numbers
| Difference (pain score points) | likely range | |
|---|---|---|
| Right after treatment (15 trials) | −1.1 | −1.27 to −0.92 |
| Under 3 months (3 trials) | −0.72 | −0.94 to −0.5 |
| 3 to 6 months (3 trials) | −0.9 | −1.4 to −0.41 |
What the trials used
- ESWT parameters across 20 RCTs
- Focused versus radial modality was not systematically distinguished (1 trial specified radial, 1 divergent, 1 voltage 6.5–11.0 kV; others unspecified). Pulses ranged from 200–300 waves (Zhang 2016) to 2,500–3,500 waves (Mo 2017), mostly 800–2,000 shocks. Intensity was patient-tolerance-guided and reported as 0.129–0.25 mJ/mm² (or 0.16–2 mJ/mm² in Wu 2017), 1.0–5 bar, 6.5–11.0 kV, or 4.5 J; frequency was 5–15 Hz in most trials and 50–60 Hz in Yang 2017. Schedules spanned 2 to 10 sessions over 2 to 8 weeks. Target landmarks and anaesthesia were not reported in Table A2.
- Routine co-interventions and comparators
- Every trial compared ESWT plus a routine therapy against the identical routine therapy alone across 20 mutually exclusive regimens (no sham ESWT): manual therapy alone (4 trials: Chen 2014, Li 2018, Xie 2019, Xu 2016), ultra-short-wave therapy + joint loosening (1 trial: Deng 2019), routine rehabilitation therapy (4 trials: Gao 2013, Huang 2014, Qin 2013 [whose article title names Maitland manipulation], Yang 2017), pain-point and/or intra-articular injection (4 trials: 2 combined with manual therapy [Cai 2019 compound betamethasone + mecobalamin + lidocaine + saline; Wang 2017 sodium hyaluronate + triamcinolone acetonide] and 2 without manual therapy [Wu 2017, Zhang 2016]), massage (2 trials: Ding 2013, Yang 2020), acupuncture or warming acupuncture (2 trials: Wang 2018, Mo 2017), kinesio taping (1 trial: Choi 2017), traditional Chinese medicine fumigation (1 trial: Yang 2019), and oral corticosteroid + TENS (1 trial: Shao 2020).
Who took part
Patients with frozen shoulder—mostly in the stiff adhesive phase, including one trial in people with diabetes—across 20 trials (19 published in Chinese, 1 in English).
Side effects
The study does not report side effects.
All the numbers and the full appraisal
The results, in numbers.
Patients diagnosed with frozen shoulder with pain and restricted joint movement across 20 RCTs (19 published in Chinese and 1 in English in a Korean physical therapy journal, Choi 2017; per-arm sample sizes 10–65 in Table A2; overall unique participant sum not printed in text). Eighteen trials enrolled patients in the adhesive phase and 2 trials (Ding 2013, Xie 2019) in the overlap of the painful freezing and adhesive phases; 1 trial (Shao 2020) specifically enrolled patients with diabetes mellitus complicated by frozen shoulder.
Pain intensity (VAS), immediate post-treatment3 reported outcomes
Pain intensity (VAS), immediate post-treatment
Visual Analog Scale (VAS) VAS points (native range not stated in Methods; trial means 0.6–7.0)
ESWT plus routine treatments versus routine treatments alone
15 studies · I² = 40%; Chi² = 23.40, df = 14 (P = 0.05); Tau² = 0.04
Inverse-variance random-effects meta-analysis (RevMan 5.3)
Across 15 unique RCTs (544 experimental and 540 control participants in Figure 3), adding ESWT to routine care lowered post-treatment VAS pain by 1.10 points more than routine care alone, with moderate heterogeneity.
Analysis details and source
Lower VAS scores indicate less pain. Summed participant count is not printed as a single figure in the paper (RevMan prints 544 and 540 separately). Note that Table A2 lists Cai 2019 measurement times only as before treatment and 3 months after, yet Figure 3 includes both an immediate entry (Cai a 2019) and a long-term entry (Cai b 2019); Xie 2019 sample sizes are 43/44 in Table A2 versus 44/43 in Figure 3.
Pain intensity (VAS), short-term (<3 months)
Visual Analog Scale (VAS) VAS points
ESWT plus routine treatments versus routine treatments alone
I² = 39%; Chi² = 4.92, df = 3 (P = 0.18); Tau² = 0.02
Inverse-variance random-effects meta-analysis (RevMan 5.3)
Short-term VAS scores favored adjunctive ESWT by 0.72 points across 3 unique RCTs (Shao 2020, Wu 2017, Zhang 2016), although confidence interval width is artificially narrowed by double-counting Shao 2020.
Analysis details and source
Unit-of-analysis error in Figure 3 subgroup 1.4.2: Shao 2020 (27 experimental vs 26 control participants, measured at 2 and 6 weeks per Table A2) was entered twice as 'Shao et al. a 2020' and 'Shao et al. b 2020' alongside Wu 2017 (53 vs 53) and Zhang a 2016 (30 vs 30), inflating the subgroup to 4 rows and RevMan arm totals to 137 vs 135.
Pain intensity (VAS), long-term (≥3 months)
Visual Analog Scale (VAS) VAS points
ESWT plus routine treatments versus routine treatments alone
3 studies · I² = 89%; Chi² = 18.30, df = 2 (P = 0.0001); Tau² = 0.17
Inverse-variance random-effects meta-analysis (RevMan 5.3)
Across 3 RCTs (97 experimental and 96 control participants), VAS pain at 3 to 6 months was 0.90 points lower with adjunctive ESWT, with high between-trial heterogeneity (I² = 89%) that led the authors themselves to caution against firm long-term conclusions.
Analysis details and source
Figure 3 prints Z = 3.56 (P = 0.0004), whereas the Abstract (p. 1), Results (p. 5), and Discussion (p. 6) misprint P < .00001. Figure 3 Total also pools all 22 timepoint rows across 18 unique RCTs (MD −0.97, 95% CI −1.13 to −0.82, I² = 69%), counting Cai 2019 and Zhang 2016 twice and Shao 2020 three times.
Shoulder function (CMS), immediate post-treatment2 reported outcomes
Shoulder function (CMS), immediate post-treatment
Constant-Murley Score (CMS) standardized mean difference (SMD)
ESWT plus routine treatments versus routine treatments alone
3 studies · I² = 0%; Chi² = 0.36, df = 2 (P = 0.83); Tau² = 0.00
Inverse-variance random-effects meta-analysis (RevMan 5.3)
In 3 RCTs (Huang 2014, Mo 2017, Xu 2016; 80 experimental and 84 control participants), Constant-Murley shoulder function scores immediately after treatment were consistently higher when ESWT was added to routine therapy.
Analysis details and source
Higher CMS indicates better shoulder function, so positive SMD favors ESWT + routine care; Figure 4 mistakenly left RevMan's default axis labels ('Favours [experimental]' on negative left, 'Favours [control]' on positive right) unreversed. Note also that Mo 2017 had high risk of randomization bias and Xu 2016 had high risk of other bias in Figure 2A.
Shoulder function (CMS), 12-week follow-up (single RCT)
Constant-Murley Score (CMS) standardized mean difference (SMD)
ESWT plus oral corticosteroid and TENS versus oral corticosteroid and TENS alone (Shao 2020)
1 study · Not applicable (single trial)
Single-trial standardized mean difference in RevMan 5.3
Post-treatment follow-up of shoulder function beyond the immediate visit came from a single trial of diabetic frozen shoulder (Shao 2020, 27 experimental vs 26 control participants: 78.3 ± 14.9 vs 64.8 ± 13.9 at 12 weeks).
Analysis details and source
In Figure 4 subgroup 2.3.3 ('CMS-short term'), the 2-week (SMD 0.61, 0.06–1.16) and 6-week (SMD 0.70, 0.14–1.26) visits of the same Shao 2020 trial were pooled together as if independent (SMD 0.66, 0.26–1.05, P = 0.001; arm totals inflated to 54 vs 52), and Figure 4 Total pooled all 6 rows across 4 trials counting Shao 2020 three times (SMD 1.13, 0.76–1.49, I² = 57%).
External rotation range of movement (ER ROM), immediate1 reported outcome
External rotation range of movement (ER ROM), immediate
Shoulder external rotation goniometry (ER ROM) degrees
ESWT plus routine treatments versus routine treatments alone
4 studies · I² = 93%; Chi² = 45.32, df = 3 (P < 0.00001); Tau² = 40.53
Inverse-variance random-effects meta-analysis (RevMan 5.3)
Across 4 RCTs (97 experimental and 95 control participants), external rotation immediately after treatment averaged 10.31° higher with adjunctive ESWT, ranging from 1.13° (−10.91° to 13.17°) in Choi 2017 to 18.87° (13.84° to 23.90°) in Deng 2019, with extreme heterogeneity (I² = 93%).
Analysis details and source
Higher degrees reflect better external rotation, so positive MD favors ESWT + routine care; Figure 5 left RevMan's default axis labels ('Favours [experimental]' on negative left, 'Favours [control]' on positive right) unreversed. Figure 5 prints Z = 2.95 (P = 0.003), whereas the Abstract, Results, and Discussion print P < .003.
How treatment was delivered
Focused versus radial modality was not systematically distinguished (1 trial specified radial, 1 divergent, 1 voltage 6.5–11.0 kV; others unspecified). Pulses ranged from 200–300 waves (Zhang 2016) to 2,500–3,500 waves (Mo 2017), mostly 800–2,000 shocks. Intensity was patient-tolerance-guided and reported as 0.129–0.25 mJ/mm² (or 0.16–2 mJ/mm² in Wu 2017), 1.0–5 bar, 6.5–11.0 kV, or 4.5 J; frequency was 5–15 Hz in most trials and 50–60 Hz in Yang 2017. Schedules spanned 2 to 10 sessions over 2 to 8 weeks. Target landmarks and anaesthesia were not reported in Table A2.
Every trial compared ESWT plus a routine therapy against the identical routine therapy alone across 20 mutually exclusive regimens (no sham ESWT): manual therapy alone (4 trials: Chen 2014, Li 2018, Xie 2019, Xu 2016), ultra-short-wave therapy + joint loosening (1 trial: Deng 2019), routine rehabilitation therapy (4 trials: Gao 2013, Huang 2014, Qin 2013 [whose article title names Maitland manipulation], Yang 2017), pain-point and/or intra-articular injection (4 trials: 2 combined with manual therapy [Cai 2019 compound betamethasone + mecobalamin + lidocaine + saline; Wang 2017 sodium hyaluronate + triamcinolone acetonide] and 2 without manual therapy [Wu 2017, Zhang 2016]), massage (2 trials: Ding 2013, Yang 2020), acupuncture or warming acupuncture (2 trials: Wang 2018, Mo 2017), kinesio taping (1 trial: Choi 2017), traditional Chinese medicine fumigation (1 trial: Yang 2019), and oral corticosteroid + TENS (1 trial: Shao 2020).
The article does not report adverse events or tolerability outcomes. Although Methods mention extracting dichotomous event ratios, no harms or dichotomous outcomes are presented anywhere in the text, forest plots, or Appendix Table A2.
Unblinded add-on designs and risk-of-bias contradiction (extractor-identified): none of the 20 RCTs included a sham ESWT control. Results text (p. 3) asserts that 18 studies had low risk of performance and detection bias, directly contradicting Figure 2 (p. 4), where 0% of entries had low risk of performance bias, only 1 study (Cai 2019, entered twice) had low risk of detection bias, and 20 trials were plotted as 24 rows.
Repeated-timepoint double counting and plotting errors (extractor-identified): Shao 2020 was entered twice (2-week and 6-week visits) inside both short-term VAS (1.4.2) and short-term CMS (2.3.3), and overall VAS and CMS totals pooled multiple visits of Cai 2019, Zhang 2016, and Shao 2020 as independent trials. Figures 4 and 5 left RevMan's default axis labels inverted for higher-is-better outcomes; long-term VAS p-value is P = 0.0004 in Figure 3 versus P < .00001 in text; RevMan random-effects models were used even when I² = 0% despite Methods specifying fixed-effects when I² ≤ 50% and PQ ≥ .1; and Table A1 search terms anomalously included 'Pes Anserine Bursitis' and 'High-Intensity Focused Ultrasound'.
Clinical heterogeneity, follow-up, and missing harms/registration (author- and extractor-noted): ESWT modality (focused vs radial), energy/pressure units, and routine background therapies varied widely; 16 of 20 trials reported only immediate post-treatment outcomes; short- and long-term CMS relied on a single diabetic frozen-shoulder RCT (Shao 2020); long-term VAS (I² = 89%) and immediate ER ROM (I² = 93%) were highly heterogeneous; no PROSPERO registration or publication-bias test was reported; and harms were omitted. Funded by Chinese national, provincial, municipal, and hospital grants; no commercial conflicts reported.
Findings checked against the full source by a separate automated reviewer.
Limitations noted by the reviewers
- Unblinded add-on designs and risk-of-bias contradiction (extractor-identified): none of the 20 RCTs included a sham ESWT control. Results text (p. 3) asserts that 18 studies had low risk of performance and detection bias, directly contradicting Figure 2 (p. 4), where 0% of entries had low risk of performance bias, only 1 study (Cai 2019, entered twice) had low risk of detection bias, and 20 trials were plotted as 24 rows.
- Repeated-timepoint double counting and plotting errors (extractor-identified): Shao 2020 was entered twice (2-week and 6-week visits) inside both short-term VAS (1.4.2) and short-term CMS (2.3.3), and overall VAS and CMS totals pooled multiple visits of Cai 2019, Zhang 2016, and Shao 2020 as independent trials. Figures 4 and 5 left RevMan's default axis labels inverted for higher-is-better outcomes; long-term VAS p-value is P = 0.0004 in Figure 3 versus P < .00001 in text; RevMan random-effects models were used even when I² = 0% despite Methods specifying fixed-effects when I² ≤ 50% and PQ ≥ .1; and Table A1 search terms anomalously included 'Pes Anserine Bursitis' and 'High-Intensity Focused Ultrasound'.
- Clinical heterogeneity, follow-up, and missing harms/registration (author- and extractor-noted): ESWT modality (focused vs radial), energy/pressure units, and routine background therapies varied widely; 16 of 20 trials reported only immediate post-treatment outcomes; short- and long-term CMS relied on a single diabetic frozen-shoulder RCT (Shao 2020); long-term VAS (I² = 89%) and immediate ER ROM (I² = 93%) were highly heterogeneous; no PROSPERO registration or publication-bias test was reported; and harms were omitted. Funded by Chinese national, provincial, municipal, and hospital grants; no commercial conflicts reported.
Source-linked critical reading
Systematic review and meta-analysis
In 20 open-label randomized trials of frozen shoulder (mostly in the stiff adhesive phase), adding shockwave sessions to routine care such as manual mobilization, physical therapy, acupuncture, or shoulder injections lowered pain scores by roughly 1.1 points right after treatment and improved immediate shoulder function scores. Confidence in lasting benefit and range-of-motion gains is limited because none of the trials used a sham shockwave control, only four trials followed patients beyond the end of treatment, results varied widely across studies, and side effects were not reported.
In adults with frozen shoulder, does adding extracorporeal shockwave therapy (ESWT) to routine conservative or injection treatments improve pain intensity, shoulder function, and external rotation range of motion compared with the same routine treatments alone?
Systematic review and pairwise meta-analysis searching PubMed, EMBASE, Cochrane Library, CNKI, and VIP Information from inception to November 2020 for English- or Chinese-language RCTs (no protocol registration reported). From 200 records and 121 full texts screened, 20 add-on RCTs were pooled in RevMan 5.3 using inverse-variance random-effects models and Cochrane risk-of-bias appraisal.
Twenty RCTs (19 published in Chinese and 1 in English in a Korean physical therapy journal, Choi 2017; arm sizes 10–65 per group in Table A2; unique participant total not printed) enrolled adults with frozen shoulder causing pain and restricted motion, excluding rotator cuff disease, calcific tendinitis, fractures, or glenohumeral arthrosis. Eighteen trials studied the adhesive phase, two studied the painful freezing-to-adhesive overlap, and one restricted enrollment to diabetes mellitus with frozen shoulder.
Tolerance-guided ESWT added to routine care: 200–3,500 pulses (mostly 800–2,000), dosed at 0.129–0.25 mJ/mm² (0.16–2 mJ/mm² in one trial), 1.0–5 bar, 6.5–11.0 kV, or 4.5 J, at 5–15 Hz (50–60 Hz in one trial), over 2–10 sessions across 2–8 weeks. Most trials did not specify focused versus radial generation.
Identical background routine treatment alone without sham ESWT: manual therapy/joint loosening/manipulation, routine rehabilitation, massage, kinesio taping, ultra-short-wave therapy, acupuncture or warming acupuncture, traditional Chinese medicine fumigation, oral corticosteroid plus TENS, or tender-point and intra-articular betamethasone or hyaluronate-triamcinolone injections.
VAS pain intensity (18 trials), Constant-Murley Score (CMS) shoulder function (4 trials), and external rotation range of movement (ER ROM, 4 trials), grouped into immediate post-treatment, short-term (<3 months), and long-term (≥3 months: 12 weeks to 6 months). Sixteen of the 20 RCTs reported only immediate post-treatment measurements.
Adjunctive ESWT lowered immediate VAS pain across 15 RCTs (MD −1.10, 95% CI −1.27 to −0.92; P < .00001; I² = 40%), short-term VAS across 3 RCTs entered as 4 rows (MD −0.72, −0.94 to −0.50; I² = 39%), and ≥3-month VAS across 3 RCTs with wide inconsistency (MD −0.90, −1.40 to −0.41; P = .0004 in Figure 3; I² = 89%). Immediate CMS favored adjunctive ESWT in 3 RCTs (SMD 1.54, 1.19 to 1.89; I² = 0%), whereas <3-month (SMD 0.66, 2 duplicated visits) and 12-week CMS (SMD 0.92, 0.35 to 1.49) came solely from Shao 2020. Immediate ER ROM averaged 10.31° higher across 4 RCTs (95% CI 3.46° to 17.17°; P = .003; I² = 93%).
The review does not report adverse events, treatment-related pain flares, or withdrawals. Omission of harms data leaves the tolerability of shockwaves over an inflamed frozen shoulder unaddressed.
Zero trials used sham ESWT, and the text claim that 18 trials had low performance and detection bias contradicts Figure 2 (0% low performance bias; 24 rows plotted for 20 studies). Shao 2020's 2- and 6-week visits were double-counted in short-term VAS and CMS, and multi-visit studies were counted two to three times in overall VAS and CMS totals. Figures 4 and 5 left RevMan's default axis labels unreversed for higher-is-better scales, long-term VAS P-values differ between text and Figure 3, publication bias was not tested, and harms were omitted. Chinese public and hospital grants; no commercial conflicts reported.
Applies mainly to predominantly Chinese-language rehabilitation trial settings adding ESWT to manual therapy, physical modalities, or injections during the adhesive phase of frozen shoulder. Because all comparisons were unblinded add-on designs and most stopped right after treatment, immediate symptom gains are plausible, whereas independent long-term benefit and optimal focused-versus-radial dosing remain unsettled.
Sham-controlled, participant- and assessor-blinded RCTs of clearly specified radial or focused ESWT added to standardized physical therapy across distinct frozen-shoulder stages, with follow-up to 6–12 months and prospective harms monitoring.
Read the original article.
Extracorporeal Shockwave Therapy as an Adjunctive Therapy for Frozen Shoulder: A Systematic Review and Meta-analysis.
Zhang R, Wang Z, Liu R, Zhang N, Guo J, Huang Y. · Orthop J Sports Med · 2022
Open the publication record or available full-text files.
Checked against the full paper · Clinical review: Dr. Marcus Yu Bin Pai, · How we review →