Radial acoustic shock waves combined with picosecond laser for tattoo removal · Randomized trial · 2025
Does adding radial shockwave speed up picosecond laser tattoo removal?
In this split-tattoo trial, using radial shockwaves to clear laser whitening and allow a second laser pass per visit sped up fading over 4 sessions. Blinded photo grading favoured the shockwave half (odds ratio 5.44), and patients rated shockwaves less painful than laser firing (about 2.6 vs 5.8 out of 10).
Faster fading with shockwave-assisted double laser pass- adults with light-to-medium skin tones
- 32
- sessions, every 4 to 6 weeks
- 4
- split tattoos evaluated before session 5
- 26
Good to know: Funded by Zimmer Aesthetics (the shockwave maker), with a co-author as consultant; the shockwave half also received two laser passes per visit versus one.
Kiritsi D, Bakirtzi A, Athanasiou I, et al. JEADV Clinical Practice, 2025 · Read the paper ↗
How this study worked
What happened
Blinded photo rating of better tattoo fading
Odds ratio after 4 sessions · above 1 favours shockwave + 2 laser passes
Show the numbers
| Odds ratio | likely range | |
|---|---|---|
| Better fading after 4 visits | 5.44 | 1.41 to 21.05 |
The treatment
Shockwave + 2 laser passes
Radial, 4 sessions
- Sessions
- 4
- Numbing
- Not mentioned
- Device
- ZWAVE (Zimmer Aesthetics)
- Everyone also got
- Two passes of Discovery Pico Plus picosecond laser per visit (2 min of shockwaves after each pass); device energy and pulse settings were not reported
Compared with: A single pass of the same picosecond laser on the opposite half of each tattoo, every 4 to 6 weeks
Settings are what each study used, not a prescription.
This protocol among the library’s
Each dot is a group treated with shockwaves in a study in this library, at the midpoint when the paper gave a range. The dark dots are this study.
Of the other 112 groups: 69 lower, 24 the same, 19 higher.
Who took part
32 healthy adults (22 women, 10 men) with Fitzpatrick skin types I–III and 37 professional tattoos at a clinic in Freiburg, Germany; 10 stopped early, leaving 26 tattoos evaluated after 4 visits.
Side effects
Almost everyone had expected itching, crusting or blistering after laser sessions. Three of 26 tattoos developed pale, slightly thinned skin patches that were more visible on the shockwave side.
All the numbers and the full appraisal
The results, in numbers.
Thirty-two healthy adults (>18 years; 22 women, 10 men; age mean/range not reported) with Fitzpatrick skin types I–III and 37 professionally applied tattoos recruited at a single center in Freiburg, Germany (Praxis am Bromberg). Exclusion criteria included pregnancy or planned pregnancy during the study, immune deficiency or wound-healing disorders, electronic/metal/plastic implants at the tattoo site, and prior tattoo removal procedures at the site. Ten participants stopped treatment or could not follow protocol procedures, leaving 26 tattoos evaluated through Visit 4 (before the fifth laser session).
Split-lesion intra-individual design: all 32 enrolled participants (37 tattoos) had one randomly assigned half of each tattoo allocated to laser plus SAW. Ten participants discontinued/could not follow protocol, leaving 26 tattoos evaluated at Visit 4; the exact number of analyzed participants is not explicitly printed (32 minus 10 equals 22, though Abstract p. 1020 writes '3/26 participants', conflating tattoos with people).
Contralateral half of each of the same 37 enrolled tattoos (32 participants); 26 tattoos evaluated through Visit 4 after 10 participants discontinued.
Blinded photographic assessment of superior tattoo clearance1 reported outcome
Blinded photographic assessment of superior tattoo clearance
Standardized clinical photographs graded by two blinded dermatology reviewers (G.D. and G.S.) identifying the side with better tattoo removal; analyzed by direct logistic regression Odds ratio (OR >1 favors laser plus SAW)
Picosecond laser (2 passes) plus radial SAW versus single-pass picosecond laser alone (26 evaluated split tattoos)
Direct logistic regression; Cox & Snell R² = 15.2%, Nagelkerke R² = 20.2%, correctly classifying 70% of cases (unadjusted for within-patient clustering across multiple tattoos).
Logarithmic ratio scale.
In blinded photographic evaluation of 26 split tattoos before the 5th session, the acoustic shock wave plus double-pass laser side had higher odds of being judged more efficaciously cleared than the single-pass laser side (OR 5.44, 95% CI 1.41–21.05; Fig. 2 shows ~70% vs ~30% clearance). Both Abstract and Results print p=0.14 despite the 95% CI excluding 1.0.
Analysis details and source
Preserved pValue='0.14' exactly as printed on pp. 1020 and 1022; mathematically an OR of 5.44 with 95% CI 1.41–21.05 corresponds to p≈0.014, suggesting a probable typographical omission of a zero. Exact binary event counts per side are not printed in the text (Fig. 2 plots percentages only). Methods p. 1021 calls the reviewers 'unaffiliated', whereas Results p. 1022 identifies them as co-authors G.D. and G.S.
Patient-rated pigment clearance (5-point Likert scale)1 reported outcome
Patient-rated pigment clearance (5-point Likert scale)
5-point Likert scale assessing whether the SAW-treated side showed improved fading (1 = no difference, 2 = slight difference, 3 = clear difference, 4 = more clear difference, 5 = extreme difference) Likert score (1–5)
At Visit 2, 17 participants reported improved fading on the SAW-treated half with a mean score of 2.9/5 ('clear difference'). At Visit 4 (before the 5th session), the mean score for the SAW-treated half was 3.9/5 ('more clear difference'), while 3 participants (printed as '3/26 participants' in Abstract p. 1020) stated the laser-only half appeared slightly better. Authors noted the added benefit appeared smaller in heavily inked black tattoos.
Analysis details and source
Retained qualitatively because the paper reports only single-side comparative Likert means without standard deviations, ranges, or statistical tests, and participants were not blinded to which half received ZWAVE and a second laser pass.
Procedural pain during laser and shockwave applications (VAS)1 reported outcome
Procedural pain during laser and shockwave applications (VAS)
Visual Analogue Scale (VAS, 0 = no pain to 10 = worst imaginable pain) Points (0–10)
Mean procedural VAS pain was lower during ZWAVE acoustic shock wave delivery than during picosecond laser firing: at Visit 1, mean VAS was 5.8/10 during the first laser pass and 5.5/10 during the second laser pass versus 2.6/10 during both ZWAVE applications; at Visit 4, mean VAS remained 5.8/10 (first laser pass) and 5.7/10 (second laser pass) while dropping to 1.8/10 during both ZWAVE applications.
Analysis details and source
Retained qualitatively because only point means are printed (no SDs, medians, IQRs, or hypothesis tests). Note that these values compare pain during laser firing versus pain during ZWAVE delivery, rather than cumulative total-session pain on the single-pass side versus the double-pass-plus-SAW side.
How treatment was delivered
Four sessions at 4–6 week intervals using the Discovery Pico Plus picosecond laser (Quanta System, Samarate, Italy) and radial acoustic shock wave device ZWAVE (Zimmer Aesthetics, Neu-Ulm, Germany). Sequence on the combination half: first picosecond laser pass -> ZWAVE applied for 2 min -> second picosecond laser pass once whitening sufficiently cleared -> ZWAVE applied for 2 more min. Laser wavelength, fluence, spot size, pulse duration, local anesthesia/cooling, and ZWAVE pressure/energy, frequency, and pulse count were not reported.
Computer-randomized contralateral half of the same tattoo received a single-pass picosecond laser session (Discovery Pico Plus) at each of the 4 visits (4–6 week intervals), without ZWAVE and without a second laser pass.
All participants except one experienced itching, crusting, or blistering after laser sessions (known laser effects), diminishing over time to 7 patients reporting adverse effects at Visit 4. Side effects were more prominent on the SAW side in 4 tattoos (vs 3 on laser-only) at Visit 1, and in 2 tattoos (vs 1 on laser-only) at Visit 4. Notably, hypopigmented, slightly atrophic areas developed in 3 tattoos at Visit 4 and were more obvious on the SAW-treated side (Fig. 1, Tattoo 24, p. 1022). Funded by Zimmer Aesthetics, which also supplied the ZWAVE device; corresponding author Dr. Hans Bayer serves as a consultant for Zimmer Aesthetics (pp. 1020, 1023).
Confounded laser pass count: the SAW-treated half received two picosecond laser passes per session (enabled by SAW clearing cavitation whitening), whereas the control half received only one laser pass, so the trial evaluates a SAW-assisted double-pass strategy rather than an isolated shockwave effect with equal laser exposure.
High attrition without intention-to-treat analysis (author-acknowledged, Discussion p. 1023): 10 of 32 enrolled participants stopped treatment or could not follow the protocol, reducing evaluated tattoos from 37 to 26 (30% lesion loss), with no baseline table or comparison of dropouts versus completers.
Omitted device dosimetry and reporting discrepancies: neither picosecond laser settings (wavelength, fluence, spot size) nor ZWAVE parameters (bar, Hz, pulse count) are reported; Abstract and Results print p=0.14 alongside OR 5.44 (95% CI 1.41–21.05); reviewers are called 'unaffiliated' on p. 1021 but identified as co-authors on p. 1022; and hypopigmented atrophic changes in 3 tattoos (more obvious on the SAW side) are downplayed in the Abstract and Discussion.
Manufacturer sponsorship, author conflict of interest, and narrow skin-type scope: funded by ZWAVE manufacturer Zimmer Aesthetics (which supplied the device) with corresponding author consultancy, restricted to Fitzpatrick skin types I–III, and no trial registry number reported.
Findings checked against the full source by a separate automated reviewer.
Limitations noted by the reviewers
- Confounded laser pass count: the SAW-treated half received two picosecond laser passes per session (enabled by SAW clearing cavitation whitening), whereas the control half received only one laser pass, so the trial evaluates a SAW-assisted double-pass strategy rather than an isolated shockwave effect with equal laser exposure.
- High attrition without intention-to-treat analysis (author-acknowledged, Discussion p. 1023): 10 of 32 enrolled participants stopped treatment or could not follow the protocol, reducing evaluated tattoos from 37 to 26 (30% lesion loss), with no baseline table or comparison of dropouts versus completers.
- Omitted device dosimetry and reporting discrepancies: neither picosecond laser settings (wavelength, fluence, spot size) nor ZWAVE parameters (bar, Hz, pulse count) are reported; Abstract and Results print p=0.14 alongside OR 5.44 (95% CI 1.41–21.05); reviewers are called 'unaffiliated' on p. 1021 but identified as co-authors on p. 1022; and hypopigmented atrophic changes in 3 tattoos (more obvious on the SAW side) are downplayed in the Abstract and Discussion.
- Manufacturer sponsorship, author conflict of interest, and narrow skin-type scope: funded by ZWAVE manufacturer Zimmer Aesthetics (which supplied the device) with corresponding author consultancy, restricted to Fitzpatrick skin types I–III, and no trial registry number reported.
Source-linked critical reading
Single-center randomized split-lesion controlled trial in Germany; 32 adults (37 tattoos) enrolled, 26 tattoos evaluated after 4 sessions.
In adults with Fitzpatrick skin types I–III undergoing picosecond laser tattoo removal, using radial acoustic shock waves to clear whitening and allow a second laser pass per session accelerated fading over four visits compared with a single laser pass, with lower pain during shockwave delivery than during laser pulses. Because 3 of 26 tattoos developed hypopigmented, slightly atrophic patches more visible on the shockwave side, dropout was high, device settings were omitted, and the study was manufacturer-funded, independent confirmation is needed.
In adults with Fitzpatrick skin types I–III seeking picosecond laser tattoo removal, does adding radial acoustic shock wave therapy to clear post-laser whitening and allow a second laser pass per visit achieve faster tattoo clearance over four sessions than a single-pass picosecond laser alone?
Single-center prospective randomized split-lesion controlled trial conducted at Praxis am Bromberg, Freiburg, Germany (ethics committee approval F-2021-154; no trial registration number reported). Computer randomization assigned which half of each tattoo received single-pass laser versus sequential laser plus acoustic shock waves across 4 sessions spaced 4–6 weeks apart, with blinded photographic grading by two co-authors.
Thirty-two healthy adults (>18 years; 22 women, 10 men) with Fitzpatrick skin types I–III and 37 professionally applied tattoos. Pregnancy, immunodeficiency or wound-healing conditions, local implants, and prior tattoo removal at the site were excluded. Ten participants discontinued or could not follow protocol procedures, leaving 26 tattoos evaluated before session 5.
Four sessions spaced 4–6 weeks apart using the Discovery Pico Plus picosecond laser (Quanta System, Italy) and radial acoustic shock wave device ZWAVE (Zimmer Aesthetics, Germany). On the combination half: laser pass 1 -> 2 min ZWAVE -> laser pass 2 after whitening cleared -> 2 min ZWAVE. Exact laser parameters (wavelength, fluence, spot size) and ZWAVE settings (pressure, frequency, pulse count) were not reported.
The randomly assigned contralateral half of each tattoo received a single picosecond laser pass per session (4 sessions at 4–6 week intervals), without ZWAVE and without a second laser pass.
Blinded visual comparison of standardized photographs (baseline vs before session 5) by two reviewers (co-authors G.D. and G.S.) to identify which half cleared better (direct logistic regression), patient-rated fading on a 1–5 Likert scale at Visits 2 and 4, procedural pain on a 0–10 VAS during each laser pass and ZWAVE step, and local adverse events at every visit.
Blinded photographic grading of 26 split tattoos favored the laser plus SAW (double-pass) half (OR 5.44, 95% CI 1.41–21.05; printed p=0.14 on pp. 1020 and 1022 despite the CI excluding 1.0; Fig. 2 shows ~70% vs ~30% clearance, Nagelkerke R²=20.2%). Patient-rated fading favored the SAW half (mean 2.9/5 at Visit 2 across 17 reporting improved fading; 3.9/5 at Visit 4, with 3/26 rating laser-only slightly better), with smaller apparent gains in heavily inked black tattoos. Mean procedural VAS pain was 5.8/10 and 5.5/10 during laser passes vs 2.6/10 during ZWAVE at Visit 1, and 5.8/10 and 5.7/10 vs 1.8/10 at Visit 4 (no SDs or comparative p-values reported).
All participants except one had expected post-laser itch, crusting, or blistering (diminishing to 7 patients by Visit 4; more prominent on the SAW side in 4 vs 3 tattoos at Visit 1 and 2 vs 1 at Visit 4). Hypopigmented, slightly atrophic areas appeared in 3 tattoos at Visit 4 and were more obvious on the SAW-treated side (Fig. 1, Tattoo 24). Supported by Zimmer Aesthetics (which provided the ZWAVE device); corresponding author Dr. Hans Bayer is a consultant for Zimmer Aesthetics.
Because SAW enabled a second laser pass per visit, the combination side received double the laser passes of the control side. Ten of 32 participants dropped out (11 of 37 tattoos lost) with no intention-to-treat analysis. Laser and shockwave parameters were completely omitted, printed p=0.14 conflicts with the 95% CI (1.41–21.05), reviewers described as 'unaffiliated' in Methods were co-authors in Results, hypopigmented atrophic areas on the SAW side were minimized in conclusions, and manufacturer sponsorship introduces potential bias.
Applies to adults with Fitzpatrick skin types I–III seeking faster picosecond laser tattoo clearance who can tolerate two laser passes per visit. Clinicians should weigh the potential for fewer total visits against the omitted dosimetry and the observed hypopigmented atrophic changes in 3 of 26 tattoos, especially in darker skin types not represented here.
Independently funded randomized trials with complete laser and shockwave settings, head-to-head comparisons against other multi-pass whitening-clearance methods (R20 or perfluorodecalin), objective pigment spectrophotometry, Fitzpatrick IV–VI representation, and long-term pigment/scar safety follow-up.
Read the original article.
Evaluation of Combined Treatment With Picosecond Laser and Acoustic Shock Wave Therapy for Tattoo Removal: A Prospective Randomized Controlled Trial
Kiritsi D, Bakirtzi A, Athanasiou I, Damiani G, Stanislawski G, Bayer H · JEADV Clinical Practice · 2025
Open the publication record or available full-text files.
Checked against the full paper · Clinical review: Dr. Marcus Yu Bin Pai, · How we review →